pvlib.inverter.pvwatts¶
-
pvlib.inverter.
pvwatts
(pdc, pdc0, eta_inv_nom=0.96, eta_inv_ref=0.9637)[source]¶ NREL’s PVWatts inverter model.
The PVWatts inverter model 1 calculates inverter efficiency \(\eta\) as a function of input DC power
\[\eta = \frac{\eta_{nom}}{\eta_{ref}} (-0.0162\zeta - \frac{0.0059} {\zeta} + 0.9858)\]where \(\zeta=P_{dc}/P_{dc0}\) and \(P_{dc0}=P_{ac0}/\eta_{nom}\).
Output AC power is then given by
\[P_{ac} = \min(\eta P_{dc}, P_{ac0})\]- Parameters
pdc (numeric) – DC power. Same unit as
pdc0
.pdc0 (numeric) – DC input limit of the inverter. Same unit as
pdc
.eta_inv_nom (numeric, default 0.96) – Nominal inverter efficiency. [unitless]
eta_inv_ref (numeric, default 0.9637) – Reference inverter efficiency. PVWatts defines it to be 0.9637 and is included here for flexibility. [unitless]
- Returns
power_ac (numeric) – AC power. Same unit as
pdc0
.
Notes
Note that
pdc0
is also used as a symbol inpvlib.pvsystem.pvwatts_dc()
.pdc0
in this function refers to the DC power input limit of the inverter.pdc0
inpvlib.pvsystem.pvwatts_dc()
refers to the DC power of the modules at reference conditions.See also
References
- 1
A. P. Dobos, “PVWatts Version 5 Manual,” http://pvwatts.nrel.gov/downloads/pvwattsv5.pdf (2014).