pvlib.temperature.sapm_cell_from_module¶
-
pvlib.temperature.
sapm_cell_from_module
(module_temperature, poa_global, deltaT, irrad_ref=1000.0)[source]¶ Calculate cell temperature from module temperature using the Sandia Array Performance Model.
See 1 for details on the Sandia Array Performance Model.
- Parameters
- Returns
numeric, values in degrees C.
Notes
The model for cell temperature \(T_{C}\) is given by Eq. 12 in 1.
(1)¶\[T_{C} = T_{m} + \frac{E}{E_{0}} \Delta T\]The module back surface temperature \(T_{m}\) is implemented in
sapm_module()
.Model parameters depend both on the module construction and its mounting. Parameter sets are provided in 1 for representative modules and mounting, and are coded for convenience in
TEMPERATURE_MODEL_PARAMETERS
.Module
Mounting
a
b
\(\Delta T [C]\)
glass/glass
open rack
-3.47
-0.0594
3
glass/glass
close roof
-2.98
-0.0471
1
glass/polymer
open rack
-3.56
-0.075
3
glass/polymer
insulated back
-2.81
-0.0455
0
References
- 1(1,2,3)
King, D. et al, 2004, “Sandia Photovoltaic Array Performance Model”, SAND Report 3535, Sandia National Laboratories, Albuquerque, NM.